Brand Name : anlaitech

Model Number : AL-MODULAR CLEAN ROOM

Certification : CE , FAT, CLASS REPORT

Place of Origin : CHINA

MOQ : 1set of china clean room

Payment Terms : L/C, T/T, Western Union

Delivery Time : 12WORKING DAYS.

Packaging Details : standard exporting packing for clean room china

Name : Prefabricated Class 10000 Hardwall Clean Room CNC ISO 7 220V

Material : Sandwich panel stainless steel

Product Name : clean room, lab clean room, modular clean room, cleanroom

Application : lab clean room, optics clean room, electronical clean room,Pharmaceutical clean room..etc

Clean Class Level : 10000

Power supply : 220V/50Hz

Contact Now

Prefabricated Hardwall Clean Room CNC ISO 7 Class 10,000 Cleanrooms

An ISO 7 clean room (Class 10,000 cleanroom) is a hard-sided wall manufactured facility that utilizes HEPA filtration systems to maintain air cleanliness levels of a maximum of 10,000 particles (≥0.5µm) per cubic foot. Class 10,000 cleanroom filtration systems must provide filter coverage of 15-25% and – a minimum of 60 air changes per hour. The standard air flow rate for an ISO 7 filtration system is 9-16 CFM per square foot.

Cleanrooms By anlaitech produces fully functional ISO 7 cleanrooms that meet all required specifications and requirements. We provide the layout, square footage, and features that your project specifications require. The custom, flexible, modular construction of our ISO 7 clean rooms makes them easy to expand, reconfigure, or relocate as your cleanroom needs evolve.

CLEAN ROOM Specification:
Model item
ISO 7 CLEAN ROOM
AL-CS4*6/C7
AL-CS5*10/C7
AL-CS6*12/C7
AL-CS7*20/C7
Size(mm)
4000*6000*2500
5000*10000*2500
6000*12000*2500
7000*20000*2500
Material
Framework
Cold rolled steel /Aluminum/Stainless steel/sandwich panel
Around
Plexiglass,Soft curtain,Anti-static strip curtain/sandwich panel
Clean Class Level
10000
10000
10000
10000
HEPA filter
Size(mm)
610*610*69
1220*610*69
1220*610*69
1220*610*69
Efficiency(%)
99.99
99.99

99.99
99.99
Air flow (m3/h)
3600
7500
10800
21000
Pre filter
Size(mm)
Optional
Motor Spec
Power supply
220V/50Hz
220V/50Hz
220V/50Hz
220V/50Hz
Noise(dB)
62
63
62
63

ISO 7 Cleanroom Standards


Classification for cleanrooms ranges from ISO 1 to ISO 9, with ISO 9 being the “dirtiest” and ISO 1 being the “cleanest.” These classifications are assigned based on the maximum allowable concentration of particles per cubic foot or meter of air. ISO class 7 clean rooms were previously defined under US Federal Standard 209E but are now defined under ISO 14644-1, however, both are still regularly used as reference points.

US Federal Standard 209E: denotes the number of particles (≥0.5 µm or larger) per cubic foot (f³) of air.
ISO 14644-1: replaced federal standard 209E in 2001 but is still used as a reference. It denotes the number of particles (≥0.1µm to ≥5µm or more) per cubic meter (m³) of air.

Prefabricated Class 10000 Hardwall Clean Room CNC ISO 7 220V

ISO 7 Cleanroom Protective Requirements


Class 10,000 cleanrooms require workers to wear fewer protective garments than cleanrooms with a lower classification but still require the use of cleanroom clothing such as face masks, hair and beard covers, and lab coats or other frocks to cover street clothing. In some ISO7 cleanrooms, coveralls and gloves may also be required. Cleanroom clothing is made from nonwoven fabrics to prevent contamination from shedding material fibers. Gloves are sterile and made from latex, nitrile or other synthetic materials.

Depending on industry and application requirements, other precautionary measures may be taken to control particle count in an ISO 7 cleanroom environment. Sticky mats are often placed outside of cleanroom entrances to remove dirt and other contaminants from shoes. Pass-thru cabinets fitted with filtration systems may also be used to safely transfer products while limiting the number of people entering and exiting the room.

Cleanroom requirements vary widely based on industry standards and the type of processes being performed. Always consult with a cleanroom professional for assistance in selecting the design and classification that are best suited for your application. Common ISO 7 clean room requirements include:

Product pass throughs
HEPA fan filters
Heat welded vinyl or epoxy floors
Gowning atrium
Air locks
Air conditioners
Entrance and exit sticky mats
Sealed lighting
Bunny suit, booties, and hood requirements
Stainless steel bench and hands free sink

Prefabricated Class 10000 Hardwall Clean Room CNC ISO 7 220V

Prefabricated Class 10000 Hardwall Clean Room CNC ISO 7 220V


Product Tags:

Prefabricated Hardwall Clean Room

      

Class 10000 Hardwall Clean Room

      

220V cnc clean room

      
Buy cheap Prefabricated Class 10000 Hardwall Clean Room CNC ISO 7 220V product

Prefabricated Class 10000 Hardwall Clean Room CNC ISO 7 220V Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Guangzhou Anlai Airtech Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)